Catalog NumberWell DesignSurface TreatmentVolume (Metric) WorkingWell Shape
468667F8MaxiSorp350 μLRound, Flat Bottom (F-well)
434797F8MaxiSorp350 μLRound, Flat Bottom (F-well)
441653C8MaxiSorp250 μLRound, C-bottom
444865C8PolySorp250 μLRound, C-bottom
445101C8MaxiSorp250 μLRound, C-bottom
467120F8MediSorp350 μLRound, Flat Bottom (F-well)
467140F8MultiSorp350 μLRound, Flat Bottom (F-well)
467466F16 (2x8 wells)MaxiSorp350 μLRound, Flat Bottom (F-well)
467679F16PolySorp350 μLRound, Flat Bottom (F-well)
469078F8PolySorp350 μLRound, Flat Bottom (F-well)
469264U16Hydrophilic250 μLRound
469914F16 (2x8 wells)MaxiSorp350 μLRound, Flat Bottom (F-well)
469922F16 (2x8 wells)PolySorp350 μLRound, Flat Bottom (F-well)
469949F8MaxiSorp350 μLRound, Flat Bottom (F-well)
469957F8PolySorp350 μLRound, Flat Bottom (F-well)
473709C12MaxiSorp250 μLRound, C-bottom
473717C12PolySorp250 μLRound, C-bottom
475078U8MaxiSorp250 μLRound
475086U8PolySorp250 μLRound
6302F12Immulon 2 HB330 μLRound, Flat Bottom (F-well)
6309F12Immulon 2 HB330 μLRound, Flat Bottom (F-well)
6310F12Immulon 1 B330 μLRound, Flat Bottom (F-well)
6405F12Immulon 4 HBX330 μLRound, Flat Bottom (F-well)
95029100F8Enhanced Binding350 μLRound, Flat Bottom (F-well)
6301TS1
also known as 6301
F12Immulon 1 B330 μLRound, Flat Bottom (F-well)
Catalog number 468667
Price (USD)
630.00
Case of 60
Add to cart
Well Design:
F8
Surface Treatment:
MaxiSorp
Volume (Metric) Working:
350 μL
Well Shape:
Round, Flat Bottom (F-well)
Price (USD)
630.00
Case of 60
Add to cart

Perform applications which are delivering well-to-well reproducibility with Thermo Scientific™ Immuno Clear Standard Modules, which feature Nunc™, Immulon™ and Microtiter™ module plates developed for ELISA techniques. Manufactured to fit standard equipment, modules provide flexible use of components with small sample sizes. They are backed by industry-leading quality standards and certifications.

Features:

  • Several strip formats: Eight-well strip, 12-well strip, 16-well strip (two columns of eight wells)
  • Several well shapes: flat bottom, C bottom (radius edge), U shape wells, StarWells (wells have fins to increase the surface area and enhance performance)
  • Several surfaces to maximize assay performance
  • Modules that remain in frame when inverted
  • Stackable frame marked for lid orientation
  • Polystyrene wells in polyethylene frame
  • Ext. Dim.: 128 × 86mm

Choice of Surface:

  • Thermo Scientific™ PolySorp™, Immulon™ 1B, and Universal Binding (UB) are for adsorption of hydrophobic molecules.
  • Thermo Scientific™ Medisorp™ and Immulon 2HB are slightly hydrophilic and bind a diverse range of biomolecules.
  • Thermo Scientific™ MaxiSorp™, Immulon 4 HBX, and Enhanced Binding(EB) are hydrophilic and ideal for antibody sandwich assays.
  • Thermo Scientific™ MultiSorp™ are very hydrophilic and works well for glycans and water soluble proteins.

Ordering Information:

Modules are freestanding. Cat. No. 95029440 and 464394 are certified. Frames and modules are available separately. Sealing tape and strip caps are available. Color-coded modules are available on request. Contact your customer service or sales representative for further details.

WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov
Specifications
Binding PropertyHydrophilic
Certifications/ComplianceCertified for adsorption of IgG; CV of <5% between wells
CertifiedYes
FormatStrip Plate
LidWithout Lid
Detection MethodColorimetric
Array8 x 12
Packaging12 inner bags of 5 each
ColorClear
Product TypeStrip Plate
MaterialPolystyrene
Volume (Metric) Well400 μL
No. of Wells96
Volume (Metric) Working350 μL
SterilityNon-sterile
Surface TreatmentMaxiSorp
Well ShapeRound, Flat Bottom (F-well)
No. per Case60
No. per PackROC 5, ROS 10
Plate BlockingNone
Quantity60/Cs.
Target MoleculeAntibodies (Glycoproteins)
Well DesignF8
Unit SizeCase of 60

Frequently asked questions (FAQs)

What frames do you recommend for your Immuno Clear Standard Modules?

We recommend Frames and Accessories for Immuno Breakable Modules, BreakApart frame (Cat. No. 465404). This frame is designed to hold the Immuno Clear Standard Modules.

What length of peptide is ideal for binding to the Thermo Scientific MaxiSorp surface? What are the detection limitations?

We have tested and found that a 3 amino acid peptide (Pro, Leu, Gly) cannot be detected when passively adsorbed on the MaxiSorp surface. However, this peptide can be detected when covalently immobilized using CovaLink NH Modules and CovaLink NH2 Modules and Plates. Using covalent immobilization of small peptide residues, you can typically obtain a better orientation of the molecule and reduced problems with antibody recognition of the peptide due to masking of the epitope. We have discovered that a 7 amino acid peptide from the MHC Class II antigen can be detected when adsorbed on the MaxiSorp surface. We state that the detection limitation using the MaxiSorp surface is between 3 and 7 amino acid residues.
One additional note is that detection is contingent upon the orientation of the peptide when immobilized. If the active site is inactivated or hidden at the site facing the solid phase, no detection signal is observed.

Can I bind either single- or double-stranded DNA to the Thermo Scientific MaxiSorp surface?

Single-stranded DNA can be adsorbed to our MaxiSorp surface using approximately 10 µg ssDNA per mL PBS, pH 8.2, although the stability is uncertain. Based on our experience, ssDNA immobilized on the MaxiSorp surface is so loosely bound that it can be removed by stringent washing.
Double-stranded DNA will not bind to the MaxiSorp surface. DNA, however, can be covalently bound to Nunc NucleoLink Strips.

For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
- Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
- Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
- "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
- StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.

What is the difference between certified and non-certified MaxiSorp plates and modules?

Both of these surfaces are identical. The only difference between them is that for the certified plates, a representative sample from each manufacturing lot undergoes a Binding Capacity test. This test is an ELISA-like assay used in our quality control laboratories to ensure binding capabilities.