Improve efficiency and profitability with a checkweigher designed for better accuracy and faster speeds. The Thermo Scientific™ Global Versa GP Checkweigher is a versatile, general purpose checkweigher that scans at line speeds up to 350 packages per minute without ever sacrificing accuracy, and now it features more than 10 engineering and functionality improvements to reduce maintenance and cost of ownership. The Versa GP Checkweigher comes with a compact cantilever construction for height adjustment and is ideal for packages up to 3 kilograms (6.6 pounds).

The Global Versa GP Checkweigher Features: 

  • Ideal for food, pharmaceutical or consumer goods industries
  • Cantilever style frame allows line height adjustment from 635mm to 1145 mm on every system
  • International equipment availability and support. 
  • Screen language options include: Chinese, Croatian, Czech, Dutch, English (UK and US versions), French, German, Italian, Latvian, Polish, Portuguese, Russian, Slovenian, Spanish and Turkish. 
  • Meets or exceeds a variety of regional and international standards and is OIML MID approved. 
  • Proprietary software with advanced automatic-zero algorithms ensure accuracy standards are maintained over time, regardless of environment.
  • Sanitary design
  • Frames designed to minimize flat surfaces and slots, reducing food buildup.
  • Stainless steel conveyor beds
  • Optional stainless-steel rollers and load cells
  • Rapid-release conveyors and belts eliminate need for tools to remove or replace
  • Tool-less thumb screw adjusts belt tracking
  • Captive conveyor rollers easy to adjust
  • High-torque sealed brushless motors allow trouble-free operation and long mean time between failures (MTBF)
  • Easy-to-read color touch screens
  • Configurable security access levels
  • Intuitive menu operation
  • Proprietary  “Weigh Engine”  uses the powerful signal processing of Thermo Scientific™ AutoCalc™ for ease of product set up. 
Specifications
Air RequirementsAir – Dry, 550 - 690 kPa (80 – 1000 psi), 1000 lpm (35 CFM)*
*application dependent
DescriptionGlobal Versa GP Checkweigher
Detector Scan RateUp to 300 ppm
Washdown OptionYes - IP65
Electrical Requirements110/120 or 220/240 VAC, 50 or 60 Hz, single phase, 15A max
FrameStainless Steel
Height (English) Line24.8 - 45.3 in.
Height (Metric) Line630 to 1150 mm +/-50 mm
Operating Temperature5°C to 40°C (41°F to 104°F)
Relative Humidity20 - 90%, non-condensing
Weight Range (Metric)5-1500g
Product TypeGlobal Versa GP Checkweigher
AccuracyUp to +/-0.1 g at 2 sigma (product/speed dependent)
Display TypeColor Touchscreen
Unit SizeEach

Frequently asked questions (FAQs)

How fast can machines check the weight of pet food products?

For pet food products in cartons, cans, bottles, or pouches, a chain checkweigher offers line speeds up to 700 packages per minute. It is appropriate for both dry and wet environments.

How can I tell if final packaged pet food products are being under or overfilled?

To ensure that pet food processors are not under or overfilling packages, checkweighers are used to verify the correct weight of each package. Accurate weight avoids giving away costly product or from receiving hefty fines from regulatory bodies for underfilling.

Do checkweighers also monitor for physical contaminants?

Checkweighers do not detect physical contaminants but they can be combined with food metal detectors and X-ray inspection systems that do detect contaminants. Food metal detection systems provide reliable, cost-effective protection from even the smallest metal contaminants found anywhere in a food production process. Food X-ray inspection systems provide protection from metal, glass, stone and other dense foreign objects for almost any type of packaged, bulk, or piped product.

Food manufacturers can find metallic and non-metallic foreign objects and eliminate “wet” product effects common with metal detectors with the Thermo Scientific NextGuard X-ray Detection Systems (https://www.thermofisher.com/order/catalog/product/NEXTGUARDPRO). Designed for a wide variety of food applications, NextGuard systems offer enhanced capabilities to inspect packaged products for missing pieces or components, under and over-fills, and other quality problems.

Can checkweighers be washed down?

Checkweighers can sometimes come in contact with food products that can leak or spill. The equipment has to get washed down regularly to prevent contamination so it must meet IP65 Washdown requirements. Therefore, checkweigher components require materials that can withstand washdown using chemicals. The metal should be fully constructed of ANSI Type 304 SS (stainless steel), which is an austenite steel. For even harsher situations, ANSI 316 stainless is used; it is more impervious to corrosion than 304 SS. Equipment should meet American National Standard ANSI/IEC 60529-2004 for equipment with electrical components. This standard describes a system for classifying the degrees of protection provided by enclosures of electrical equipment for two conditions:

- The protection of persons against access to hazardous parts and protection of equipment against the ingress of solid foreign objects
- The ingress of water

Equipment should be designed with minimal flat, horizontal surfaces and slots to reduce food buildup, and use stainless steel conveyor beds. IP65 enclosures provide basic waterproof protection from water, including jet sprays used during washdown.

What factors influence weighing accuracy using checkweighers?

Proper design of the in-line checkweigher can influence accuracy. Here are some of the design factors:

- Product speed
- Product weight and size
- Product transfer onto and off of the checkweigher
- Reject method and design

In addition, conveyors must be level and aligned, belts and chains should be inspected regularly for wear or product buildup, gaps between conveyors should be minimized and infeed and weigh table belts or chains should be running at the same speeds. Other factors include the spacing between products' centers to ensure that more than one product is not on the weighing table at any one time, and calibrations should be done regularly.