Explore our protein gel options. Choose from precast polyacrylamide gel electrophoresis (PAGE) chemistries designed for specific applications including broad range, high, or low molecular weight separations, SDS-PAGE, native PAGE, or IEF. Mini gels and wider, higher throughput, midi gels are offered in a variety of well and cassette formats. Or select a system for pouring and casting your own gels.
Find the right gel for your protein
Convert from other suppliers' gels
Protein gels performance guarantee—Invitrogen precast protein gels are designed and tested to deliver superior performance, reliability, reproducibility, and consistency of quality. We guarantee it. Check out our Certificate of Analysis. No other supplier conducts such stringent quality testing.
Get started with our money-saving Protein Gels Welcome Packs
Featured protein gel categories
|  Bis-Tris Gels |  Tris-Glycine Gels |  Tris-Acetate Gels |  Tricine Gels |
Available precast gels | NuPAGE Bis-Tris Gels, Bolt Bis-Tris Plus Gels | Novex Tris-Glycine | NuPAGE Tris-Acetate | Novex Tricine |
Protein sample type | Broad range MW (6–400 kDa) | Broad range MW (6–400 kDa) | High range MW (40–500 kDa) | Low range MW (2.5–40 kDa) |
Product benefits | Neutral pH helps prevent protein degradation for high sensitivity. Load up to 60 µL per well with Bolt gels. Fast 20–35 minute run times. Room temperature storage for up to 16 months. Two buffer options: Choose MOPS buffer for higher range separations or MES buffer for lower range separations. | Traditional Laemmli-style gels with larger loading capacity—load up to 60 µL per well. | Neutral pH for better separation, transfer, and analysis of high molecular weight proteins. | Better separation, transfer, and analysis of low molecular weight proteins. |
Recommended for | Western blotting, in-gel staining, mass spectrometry, post translationally modified proteins, dilute samples, and denaturing applications. | Western blotting, in-gel staining, samples containing detergent and high salt, and denaturing or native PAGE applications. | High molecular weight proteins, Western blotting, mass spectrometry, post translationally modified proteins, and denaturing or native PAGE applications. | Low molecular weight proteins, western blotting, in-gel staining, and denaturing applications. |
Bis-Tris
Precast gels | When to use | Gel % available | Separation range | Formats available | Average run time | Shelf life |
---|
Bolt Bis-Tris Plus | - Time is crtitical
- Dilute or larger (up to 60 µL) samples
- Broad-range separation of proteins
- Western blot transfer and analysis, and all techniques in which protein integrity is crucial
| 8% 10% 12% 4–12% | 6 to 400 kDa | - Mini with larger well capacity (WedgeWell, up to 60 µL)
| 22–45 min | 16 months at room temperature |
NuPAGE Bis-Tris | - Broad-range separation of proteins
- Western blot transfer and analysis, and all techniques in which protein integrity is crucial
| 8% 10% 12% 4–12% | 1.5 to 300 kDa | | 35–50 min | 16 months at room temperature |
Tris-Glycine
Precast gels | When to use | Gel % available | Separation range | Formats available | Average run time | Shelf life |
---|
Novex Tris-Glycine | - Broad-range separation of proteins using traditional Laemmli-style gels
| 6% 8% 10% 12% 4–20% 4–12% 14% 16%
8–16%
10–20%
| 8 to 250 kDa | - Mini with larger well capacity (WedgeWell, up to 60 µL)
- Midi
| 90 min | 12 months |
Tris-Acetate
Precast gels | When to use | Gel % available | Separation range | Formats available | Average run time | Shelf life |
---|
NuPAGE Tris-Acetate | - Separation of larger proteins
| 7% 3–8% | 36 to 500 kDa | | 60 min | 8 months |
Tricine
Precast gels | When to use | Gel % available | Separation range | Formats available | Average run time | Shelf life |
---|
Novex Tricine | - Separation of small proteins and peptides
| 10% 16% | 2 to 200 kDa | | 90 min | 1–2 months |
Native Bis-Tris
Precast gels | When to use | Gel % available | Separation range | Formats available | Average run time | Shelf life |
---|
NativePAGE Bis-Tris | - Separation of native proteins
| 3–12% 4–16% | 15 to 10,000 kDa | | 90–120 min | 12 months |
IEF
Precast gels | When to use | Gel % available | Separation range | Formats available | Average run time | Shelf life |
---|
IEF | - Separation of proteins based on isoelectric point
| pH 3–7 pH 3–10 | pI 3.5 to pI 8.5 | | 150 min | 2 months |
Zymogram
Precast gels | When to use | Gel % available | Separation range | Formats available | Average run time | Shelf life |
---|
Zymogram | - Separation of proteins based on size and activity
| 10% (with gelatin) | 10 to 220 kDa | | 90 min | 2 months |
E-PAGE
Precast gels | When to use | Gel % available | Separation range | Formats available | Average run time | Shelf life |
---|
E-PAGE | - High throughput for recombination product analysis and protein profiling
| E-PAGE 96: 6% E-PAGE 48: 8% | 10 to 220 kDa | | 14–25 min | 6 months |
|  SureCast Handcast System Explore |  Empty Gel Cassettes Explore |  Bolt Empty Cassettes Explore |
Cassette type | Resuable, glass | Single use, pre-sealed | Single use, pre-sealed |
Product benefits | - Leak-free design—minimize the number of failed gels, waste less time
- Superior glass plate durability
- Unique tilt feature—minimize spillage and confidently load acrylamide solutions
- Simple component assembly—using a single-motion load-and-lock mechanism
| - Ready-to-pour cassettes, casting stand not required, cassettes sealed on three sides (no gel leakage)
- Special coating provides uniform polymerization rate for a more consistent handcast gel
| - High capacity sample wells—load up to 60 µL per well
- Ready-to-pour cassettes, casting stand not required, cassettes sealed on three sides (no gel leakage)
- Special coating provides uniform polymerization rate for a more consistent handcast gel
|
Gel dimensions | Mini: 8x8 cm (1 mm thick) | Mini: 8x8 cm (1 or 1.5 mm thick) Midi: 8x13 cm (1 mm thick) | Mini: 8x8 cm (1 mm thick) |
Gel tank | Mini Gel Tank, Xcell SureLock Mini-Cell | Mini Gels: Mini Gel Tank or XCell SureLock Mini-Cell Midi Gels: XCell4 SureLock Midi-Cell or Bio-Rad Criterion (with adapters only) | Mini Gel Tank, Xcell SureLock Mini-Cell |
Reagents | SureCast reagents, other popular polyacrylamide reagents | SureCast reagents, other popular polyacrylamide reagents | SureCast reagents, other popular polyacrylamide reagents |
Combos available | 1-, 2-, 10-, 12-, and 15-wells | 1-, 2-, 5-, 10-, 12-, 15-, and 2D-wells | 10- or 12-wells (high capacity wells) |
Featured protein gel categories
|  Bis-Tris Gels |  Tris-Glycine Gels |  Tris-Acetate Gels |  Tricine Gels |
Available precast gels | NuPAGE Bis-Tris Gels, Bolt Bis-Tris Plus Gels | Novex Tris-Glycine | NuPAGE Tris-Acetate | Novex Tricine |
Protein sample type | Broad range MW (6–400 kDa) | Broad range MW (6–400 kDa) | High range MW (40–500 kDa) | Low range MW (2.5–40 kDa) |
Product benefits | Neutral pH helps prevent protein degradation for high sensitivity. Load up to 60 µL per well with Bolt gels. Fast 20–35 minute run times. Room temperature storage for up to 16 months. Two buffer options: Choose MOPS buffer for higher range separations or MES buffer for lower range separations. | Traditional Laemmli-style gels with larger loading capacity—load up to 60 µL per well. | Neutral pH for better separation, transfer, and analysis of high molecular weight proteins. | Better separation, transfer, and analysis of low molecular weight proteins. |
Recommended for | Western blotting, in-gel staining, mass spectrometry, post translationally modified proteins, dilute samples, and denaturing applications. | Western blotting, in-gel staining, samples containing detergent and high salt, and denaturing or native PAGE applications. | High molecular weight proteins, Western blotting, mass spectrometry, post translationally modified proteins, and denaturing or native PAGE applications. | Low molecular weight proteins, western blotting, in-gel staining, and denaturing applications. |
Bis-Tris
Precast gels | When to use | Gel % available | Separation range | Formats available | Average run time | Shelf life |
---|
Bolt Bis-Tris Plus | - Time is crtitical
- Dilute or larger (up to 60 µL) samples
- Broad-range separation of proteins
- Western blot transfer and analysis, and all techniques in which protein integrity is crucial
| 8% 10% 12% 4–12% | 6 to 400 kDa | - Mini with larger well capacity (WedgeWell, up to 60 µL)
| 22–45 min | 16 months at room temperature |
NuPAGE Bis-Tris | - Broad-range separation of proteins
- Western blot transfer and analysis, and all techniques in which protein integrity is crucial
| 8% 10% 12% 4–12% | 1.5 to 300 kDa | | 35–50 min | 16 months at room temperature |
Tris-Glycine
Precast gels | When to use | Gel % available | Separation range | Formats available | Average run time | Shelf life |
---|
Novex Tris-Glycine | - Broad-range separation of proteins using traditional Laemmli-style gels
| 6% 8% 10% 12% 4–20% 4–12% 14% 16%
8–16%
10–20%
| 8 to 250 kDa | - Mini with larger well capacity (WedgeWell, up to 60 µL)
- Midi
| 90 min | 12 months |
Tris-Acetate
Precast gels | When to use | Gel % available | Separation range | Formats available | Average run time | Shelf life |
---|
NuPAGE Tris-Acetate | - Separation of larger proteins
| 7% 3–8% | 36 to 500 kDa | | 60 min | 8 months |
Tricine
Precast gels | When to use | Gel % available | Separation range | Formats available | Average run time | Shelf life |
---|
Novex Tricine | - Separation of small proteins and peptides
| 10% 16% | 2 to 200 kDa | | 90 min | 1–2 months |
Native Bis-Tris
Precast gels | When to use | Gel % available | Separation range | Formats available | Average run time | Shelf life |
---|
NativePAGE Bis-Tris | - Separation of native proteins
| 3–12% 4–16% | 15 to 10,000 kDa | | 90–120 min | 12 months |
IEF
Precast gels | When to use | Gel % available | Separation range | Formats available | Average run time | Shelf life |
---|
IEF | - Separation of proteins based on isoelectric point
| pH 3–7 pH 3–10 | pI 3.5 to pI 8.5 | | 150 min | 2 months |
Zymogram
Precast gels | When to use | Gel % available | Separation range | Formats available | Average run time | Shelf life |
---|
Zymogram | - Separation of proteins based on size and activity
| 10% (with gelatin) | 10 to 220 kDa | | 90 min | 2 months |
E-PAGE
Precast gels | When to use | Gel % available | Separation range | Formats available | Average run time | Shelf life |
---|
E-PAGE | - High throughput for recombination product analysis and protein profiling
| E-PAGE 96: 6% E-PAGE 48: 8% | 10 to 220 kDa | | 14–25 min | 6 months |
|  SureCast Handcast System Explore |  Empty Gel Cassettes Explore |  Bolt Empty Cassettes Explore |
Cassette type | Resuable, glass | Single use, pre-sealed | Single use, pre-sealed |
Product benefits | - Leak-free design—minimize the number of failed gels, waste less time
- Superior glass plate durability
- Unique tilt feature—minimize spillage and confidently load acrylamide solutions
- Simple component assembly—using a single-motion load-and-lock mechanism
| - Ready-to-pour cassettes, casting stand not required, cassettes sealed on three sides (no gel leakage)
- Special coating provides uniform polymerization rate for a more consistent handcast gel
| - High capacity sample wells—load up to 60 µL per well
- Ready-to-pour cassettes, casting stand not required, cassettes sealed on three sides (no gel leakage)
- Special coating provides uniform polymerization rate for a more consistent handcast gel
|
Gel dimensions | Mini: 8x8 cm (1 mm thick) | Mini: 8x8 cm (1 or 1.5 mm thick) Midi: 8x13 cm (1 mm thick) | Mini: 8x8 cm (1 mm thick) |
Gel tank | Mini Gel Tank, Xcell SureLock Mini-Cell | Mini Gels: Mini Gel Tank or XCell SureLock Mini-Cell Midi Gels: XCell4 SureLock Midi-Cell or Bio-Rad Criterion (with adapters only) | Mini Gel Tank, Xcell SureLock Mini-Cell |
Reagents | SureCast reagents, other popular polyacrylamide reagents | SureCast reagents, other popular polyacrylamide reagents | SureCast reagents, other popular polyacrylamide reagents |
Combos available | 1-, 2-, 10-, 12-, and 15-wells | 1-, 2-, 5-, 10-, 12-, 15-, and 2D-wells | 10- or 12-wells (high capacity wells) |
Polyacrylamide gels
All Invitrogen precast protein gels are high quality polyacrylamide gels designed to deliver superior performance, reliability, reproducibility, and consistency of quality. Our extensive portfolio of precast protein gels provides a wide variety of gel options available for your research. Whether your protein is 2.5 kDa or as large as 500 kDa, or you’re looking for separation under native conditions or by isoelectric point—we have the right gel for your application.
Our precast protein polyacrylamide gels are offered in four different chemistries. The choice of whether to use one chemistry or another depends on the abundance of the protein you’re separating, the size of the protein, and your downstream application.
SDS PAGE protein separation
For denaturing gel electrophoresis or SDS PAGE there are many options available based on the application, and size of the protein of interest. For separation of a broad range of proteins, two chemistries, Bis-Tris and Tris-glycine, have been optimized for performance and long shelf life. Choose Bis-Tris gel chemistry when you have a low abundance of protein or when your downstream applications require high protein integrity, such as posttranslational modification analysis, mass spectrometry, or sequencing. Bis-Tris chemistry provides a neutral (pH 7.0) environment during electrophoresis, which may result in better sample integrity and stability of the gel. This helps reduce protein modifications and helps produce sharp band resolution. Bis-Tris gel chemistry is offered in our Bolt Bis-Tris Plus and NuPAGE Bis-Tris gels. Bolt Bis-Tris Plus mini gels build on the legacy of the highly published NuPAGE Bis-Tris gels, feature larger capacity wells- for loading up to 60 µl per well, and can be run in as little as 20 minutes.
To separate high-abundance proteins, select our robust Novex Tris-Glycine gel chemistry, which offers maximum protein separation performance and crisp, straight bands.
For separation of high molecular weight proteins, Tris-acetate gel chemistry is recommended, offered in NuPAGE Tris-Acetate gels.
For separation of low molecular weight proteins, use Novex Tricine gels which provide increased resolution of proteins with molecular weights as low as 2.5 kDa.
Native PAGE protein separation
For separation of proteins under nondenaturing conditions or native page, three gel systems are recommended- NativePAGE Bis-Tris, Novex Tris-Glycine and NuPAGE Tris-Acetate. NativePAGE Bis-Tris gels, are based on the blue native polyacrylamide gel electrophoresis (BN-PAGE) which helps overcome the limitations of traditional native electrophoresis by providing a near-neutral operating pH and detergent compatibility. Both Novex Tris-Glycine and NuPAGE Tris-Acetate gels can be run under native and non-reducing conditions for separation of proteins by net charge, size and shape.
For separation of proteins by isoelectroctric point (pI), use Novex IEF gels. Novex IEF gels effectively create a pH gradient to separate proteins according to their unique pI.
How-to videos
How to choose the right protein gel for your research application
This webinar will highlight the different protein modifications occurring during electrophoresis, the importance of pH in sample integrity, how to choose the right gel chemistry for specific research applications, and how to introduce the right new gel chemistry in your research workflow.
How to separate proteins using an Invitrogen precast SDS-PAGE gel
This video will show you how to separate proteins by using Invitrogen Mini Gel Tank and Invitrogen precast SDS-PAGE gels.
Need help determining the best gel to use?
Find the exact gel and buffers needed for your electrophoresis experiments.
Find the right gel for your research needs based on molecular weight, downstream applications, and throughput requirements.
Learn how the right protein gel chemistry can help you achieve better protein separation and western blots.
Protein Gels Performance Guarantee
We stand behind the performance of our protein gels.
Learn more
Find the right protein gel for your experiments
| Pour your own gels with a handcast system | Value gels for screening and qualitative protein separation | Gels based on traditional Laemmli formula with 60uL
sample volume capacity | Highest resolution, longest shelf-life and western
optimized gels | Highest resolution and long shelf-life |
---|
| View
all | Order now | Order now | Order now | Order now |
---|
|  View
all handcast systems
|  Novex™ Value Tris-Glycine gels |  Novex™
WedgeWell™ Tris-Glycine gels
|  Bolt™
Gels
|  NuPAGE™
Gels
|
---|
Citations in the last
10 years | N/A | N/A | N/A | N/A (new product) | >20,000 |
---|
Protein resolution
& integrity, lot consistency & band quality | Not applicable | Good | High | High | High |
---|
Average run time | 90 min | 46 min (225V) | 60 min | 35 min | 35 min |
---|
Well format | Standard | Standard | New high-capacity wedge design | New high-capacity wedge design | Standard |
---|
Gel dimensions | Mini: 8x8 cm, 1 or 1.5 mm thick | Mini: 8x8 cm, 1 mm thick | Mini: 8x8 cm, 1 or 1.5 mm thick | Mini: 8x8.3 cm, 1 mm thick | Mini: 8x8 cm, 1 or 1.5 mm
thick
Midi: 8 x 13 cm, 1 mm thick |
---|
Shelf life | N/A | Up to 12 months | Up to 12 months | >16 months | 8 months (Tris-Acetate)
16 months (Bis-Tris) |
---|